Awwa c600-10 free pdf download

The form of chlorine shall be a 1 percent made either. No pipeline installation will be accepted by aw if the leakage is greater than that shown in the following table. Awwa c600 pdf standard ansiawwa c, installation of. Major revisions of this edition of the standard include the following. Mar 28, 2019 awwa c600 pdf standard ansiawwa c, installation of. Ansiawwa c60010 rubbergasket joints for ductileiron pressure pipe and fittings this product replaces. Thrust restraint design for ductile iron pipe design of ductile iron pipe on supports awwa standards ansiawwa c104a21. Awwa c606 grooved and shouldered joints engineering360. Established in 1881, the american water works association is the oldest and largest nonprofit, scientific and educational organization dedicated to safe and sustainable water in the world. Awwa c60010 installation of ductile iron water mains and their appurtenances. They were placed on your computer when you launched this website. Awwa c60010 installation of ductileiron mains and their. Line interior of fittings for water pipelines with cement mortar per awwa c104 and line interior of bells per standard specification section 09900, system no. This table lists maximum depths of cover for the five types of laying conditions for all standard.

Rubbergasket joints for ductileiron pressure pipe and fittings american water works association 01mar2007 52 pages. Granular materials are defined per the aashto soil classification system astm d3282 or the unified soil classification system astm d2487, with the exception that gravel beddingbackfill adjacent to the pipe is limited to 2 maximum particle size per ansiawwa c600. Installation of ductileiron water mains and their appurtenances awwa c600 05 and awwa c60505 1. Our policy towards the use of cookies techstreet, a clarivate analytics brand, uses cookies to improve your online experience. Method as per awwa c651, latest revision, section 5. Pressure and leakage tests revised january 2016 33 01 10. Measure the volume of water using a calibrated container or meter. Special specification 5766 hydrostatic tests for pressure. Thickness design of ductileiron pipe american water works association 01dec2008 64 pages.

Both awwa c201 and awwa c202 were superseded by awwa c20075, approved by the awwa. The potable water shall be chlorinated so that after a 24 hour holding period in the main, there will be a free chlorine residual of not less than 10 mgl at all points in the system when tested with standard orthotolindine solution. American water works association is an international nonprofit, scientific and educational association founded to improve water quality and supply. Documents sold on the ansi webstore are in electronic adobe acrobat pdf format.

Frequently asked questions installation ductile iron pipe. Awwa c201 was revised in 1966, and awwa c202 was revised in 1964. Separate payment will not be made for hydrostatic testing of water mains. This standard describes grooved and shouldered joints for ductileiron pipe, metallic pressure pipe of iron pipe size ips, fittings, and other components for water service. Awwa c600 standard free download keyword after analyzing the system lists the list of keywords related and the list of websites with related content, in addition you can see which keywords. Mar 25, 2018 water professionals worldwide recognize awwa standards as the standard for quality. With more than 50,000 members worldwide and 43 sections in north america, awwa advances public health, safety and welfare by uniting the efforts of the. If you need the most current awwa standard right away, just download it at awwas download centerthe water library.

3 maintain pressure within 5 psi of the test pressure after it is filled and purged of. Dec 26, 2019 awwa c600 pdf standard ansiawwa c, installation of. Awwa c60505 underground installation of polyvinyl chloride. Installation, field testing, and maintenance, fifth edition pdf. Dipra is the leading resource for design and application of ductile iron pipe in north america. Includes an illustrated guide to fire hydrants, organized by manufacturer name. All books are the property of their respective owners. Installation of ductile iron water mains and their appurtenances 2010. Ductile iron pipe standards and suggested specifications dipra.

Ductile iron pipe standards and suggested specifications. Awwa c60010 free pdf download 1cc1596b1f share on facebook. Water professionals worldwide recognize awwa standards as the standard for quality. The bulk of the material in this manual refers to drybarrel and wetbarrel fire hydrants. Includes an illustrated guide to fire hydrants, organized. Similar books awwa c600 9b awwa c600 93 awwa c60010 awwa c600 10 awwa c600 05 awwa c600 awwa c60093 awwa c600. Installation practices described are consistent with awwa c60010 installation of ductile iron water mains and their appurtenances. Installation of ductileiron water mains and their appurtenances awwa c60005 and awwa c60505 1.

Installation practices described are consistent with awwa c600 10 installation of ductile iron water mains and. Awwa c200 includes all types and classes of steel pipe, 6 in. Awwa bookstore catalog standards 2011 free download pdf ebook. Please first verify your email before subscribing to alerts your alert profile lists the documents that will be monitored. Thrust restraint design for ductile iron pipe design of ductile iron pipe on supports awwa standards ansi awwa c104a21. Along the test section, the test pressure shall not exceed pipe or thrustrestraint design pressure, shall be of at least 2 hour duration, and shall not vary by more than 5 psi for the duration of the test. Included with the purchase of m17 are two 16x22 printable pdfs. Awwa c80012 underground service line valves and fittings also included. This standard describes installation procedures for ductileiron mains and their appurtenances for potable water, wastewater, and reclaimed water.

The contractor shall provide all necessary pumps, underdrains, well point systems, and other means for removing water from trenches and other parts of the work. When not practical, work shall be done as specified by the engineer of record. Provide double thickness lining and use cement conforming to astm c150 type ii. The contractor shall submit a test report which includes the following.

Awwa c60010 installation of ductileiron water mains and their appurtenances. Published by awwa on january 14, 2017 this standard describes 3in. Awwa c, standard for installation of ductileiron water mains and their. Get answers to frequently asked questions about ductile iron pipe installation. Collected standards for service line materials awwa c90007 polyvinyl chloride pvc pressure pipe, and fabricated fittings, 4 in. Along the test section, the test pressure shall not exceed pipe or thrustrestraint design. Ductile iron mains and their appurtenances, includes much of the information outlined in this guide. Disinfection requirements shall include preventive and. Back to awwa c60010 installation of ductileiron mains and their appurtenances this standard describes installation procedures for ductileiron mains and their appurtenances for potable. Installations that require special attention, techniques. Ansiawwa c60010 thickness design of ductileiron pipe this product replaces. This standard describes underground installation and hydrostatic testing procedures for polyvinyl chloride pvc pressure pipe and fittings that comply with either ansi awwa c900, ansi awwa c905, ansi awwa c907, or ansi awwa c909. Awwa bookstore catalog standards 2011 free download pdf. Awwa c60010 installation of ductile iron water mains.

Awwa c60010 installation of ductile iron water mains and. Installation of ductileiron water mains and their appurtenances. Frequently asked questions installation print email below we provide the answers to several frequently asked questions regarding ductile iron pipe installation. Awwa c600 standard free download keyword found websites. The contractor shall furnish adequate personnel to open manholes. Test pressures for the various services and types of piping. Installation of ductileiron water mains and their appurtenances pressure class thickness in.

The test pressure shall not be less than 150 psi at the highest point. This standard covers the minimum requirements for the awwaa of ductileiron water mains and their appurtenances, including materials, dimensions, tolerances, and testing procedures. Scribd is the worlds largest social reading and publishing site. Both awwa c201 and awwa c202 were superseded by awwa c20075, approved by the awwa board of directors on jan. Awwa c, ductile iron pipe centrifugally cast in metal moulds or g. Awwa c600 installation of ductileiron mains and their. If the document is revised or amended, you will be notified by email. Awwa bookstore catalog standards 2011 free download as pdf file. Taken from the table that follows, it is offered as a convenience for quickly checking the capabilities of minimum pressure a of ductile iron pipe under a given set of conditions. If you need the most current awwa standard right away, just download it at awwas download. Manholes and lines shall be clean and free of all mud and debris at the time of inspection. Lubrication and additional cleaning should be provided by brushing both the gasket and plain. Include costs for testing, repair of defects, and retesting required in this section in appropriate unit prices bid for water.

Test pressures for the various services and types of piping are shown at the end of this section in table 15044. This site does not host pdf, doc files all document are the property of their respective owners. Installation practices described are consistent with awwa c600 10 installation of ductile iron water mains and their appurtenances. Browse related products from american water works association. Dipra representatives sit on the defining standards committees of the awwa, asme, astm, nace, nfpa, and iso organizations, ensuring that design and manufacturing standards for ductile iron pipe remain the most stringent and comprehensive in the industry. This table lists maximum depths of cover for the five types of laying conditions for all standard pressure classes. Hydrostatic testing awwa 600 free download as pdf file. Lubrication and additional cleaning should be provided by brushing both the gasket and plain end with soapy water or an approved pipe lubricant meeting the requirements of ansi awwa c111a21.

1110 825 26 703 1084 1112 153 851 990 71 1178 32 696 355 1200 1349 485 1540 1519 551 473 797 789 775 1284 963 648 328 148 1472 240 1313 676 644 1183 503 1245 241 696